Support

  1. What’s the major config difference between ‘1200 1-man’ and ‘Viva 1-man’?

    With Leica Viva creeping into hire fleets and companies updating their survey fleet, Viva is becoming more popular. The config difference when working 1-man is that all the ‘clever stuff’ is now on the controller (either the CS10 or CS15). Instead of working in “Terminal Mode”, where the RX is just a remote control, everything is now done on the...
  2. SmartNet – what’s the IP address?

    SmartNet – what’s the IP address? From 2011 onwards the Main and BackUp servers for SmartNet are as follows. Main: 217.146.121.50 / IP port is 7801 BackUp: 213.120.255.90 / IP port is 7801 Olympic Site: 217.146.121.40 / IP port is 7801
  3. Beeping Radio Handle? No communication working 1-man?

    Beeping Radio Handle? No communication working 1-man? We have had many experiences of poorly performing radio-handles; the newer series with the ‘humps’ are much better. If you lose comms when working 1-man, try and change the link number (F4-CTRL) on the instrument. This is a great way of testing whether the radio is communicating with the Total Station. If the...
  4. Can I use my old RH1200 radio-handle with Viva?

    Can I use my old RH1200 radio-handle with Viva? Sadly not; because the frequency bands are slightly difference (and you cannot program them) a Viva controller must be used in conjunction with a RH15 radio-handle.